EN50121-4 &  IEC 62236-4 standard

Demiryolu standartları Leave a comment

EN 50121-4 and IEC 62236-4, Track Side Approval
To fully comply with EN50121-4 and IEC 62236-4 a product must be designed
to meet a series a demanding standards covering EMC, vibration and power.
Track side installations needs to be more resistant to ESD, EFT, Surge, Radio
frequency magnetic field as well as Puls and Power magnetic ield.
The following comparison shows the difference between the test levels.

Generic Industry Track Side
ESD 4kV 6kV
Radio frequency magnetic field 10V/m 20V/m
EFT (fast transient) 1 kV class B * 2 kV class A *
Surge Signal L-E 1 kV 2 kV
Signal L-L N/A 2Kv
AC Pow.L-E 2 kV 2kV
AC Pow.L-L 1kV 2kV
DC Pow.L-E 0.5 kV 2 kV
DC Pow.L-L 0.5 kV 2kV
Power magnetic field 30 A/m 300 A/m
Puls magnetic field N/A 300 A/m

*Class A do not accept restart of the unit or loss of package or restart, class B do not accept
restart of the product but accept loss of data.
Refrence: www.westermo.com